Table 2. Number of spaces required for short- and long-term bicycle storage
| Col1 | Commercial, institutional, schools, healthcare | Residential | Mixed use | Retail |
|---|---|---|---|---|
| Short- term storage | At least 2.5% of all peak visitors but no fewer than four spaces per building. | At least 2.5% of all peak visitors but no fewer than four spaces per building. | Meet the storage requirements for the nonresidential and residential portions of the project separately. | At least two short- term bicycle storage spaces for every 5,000 square feet (465 square meters) but no fewer than two storage spaces per building. |
| Long- term storage | At least 5% of all regular building occupants but no fewer than four storage spaces per building, in addition to short-term storage. | At least 15% of all regular building occupants but no fewer than one storage space per three dwelling units, in addition to short term storage spaces. | At least 15% of all regular building occupants but no fewer than one storage space per three dwelling units, in addition to short term storage spaces. | At least 5% of regular building occupants but no fewer than two storage spaces per building in addition to the short-term bicycle storage spaces. |
NOTE: For New Construction only: School projects can exclude students in third grade and younger from the regular building occupant count for long-term storage. Healthcare projects can exclude patients from the regular building occupant count for long-term storage.
AND/OR
PATH 2. SHOWER AND CHANGING FACILITIES (1 POINT)
Provide access to on-site showers with changing facilities for 1% of all regular building occupants. Off-site showers and changing facilities are acceptable if they meet the needs of all occupants and are within 0.25 miles (400 meters) walking distance.
Large occupancy projects Provide at least one on-site shower with a changing facility for the first 100 regular building occupants and one additional shower for every 150 regular building occupants thereafter, up to 999 regular building occupants. After that, provide the following:
-
One additional shower for every 500 regular building occupants, for an additional 1,000– 4,999 regular building occupants.
-
One additional shower for every 1,000 regular building occupants, for the additional 5,000+ regular building occupants.
AND/OR
U.S. Green Building Council LEED v5 Reference Guide for Building Design and Construction, April 2025 Launch Edition 87