Sustainable Sites Credit

HEAT ISLAND REDUCTION

SSc5

New Construction (1–2 points) Core and Shell (1–2 points)

INTENT

To mitigate disparate impacts on microclimates and habitats caused by heat islands and extreme heat events.

REQUIREMENTS
Achievement pathwaysPoints
New Construction and Core and Shell1–2
Option 1. Nonroof and Roof1
AND/OR
Option 2. Parking Under Cover1
AND/OR
Option 3. Tree Equity1

Choose one of the following options:

Option 1. Nonroof and Roof (1 point)

Meet the following criteria for the nonroof and roof weighted average approach:

Equation 1. Weighted nonroof and roof calculation

𝐴𝑟𝑒𝑎 𝑜𝑓 𝑛𝑜𝑛𝑟𝑜𝑜𝑓 𝑚𝑒𝑎𝑠𝑢𝑟𝑒𝑠

  • [𝐴𝑟𝑒𝑎 𝑜𝑓 ℎ𝑖𝑔ℎ-𝑟𝑒𝑓𝑙𝑒𝑐𝑡𝑎𝑛𝑐𝑒 𝑟𝑜𝑜𝑓] 0.5 0.75

  • [𝐴𝑟𝑒𝑎 𝑜𝑓 𝑣𝑒𝑔𝑒𝑡𝑎𝑡𝑒𝑑 𝑟𝑜𝑜𝑓] 0.75 0.75

0.75

≥𝑇𝑜𝑡𝑎𝑙 𝑠𝑖𝑡𝑒 𝑝𝑎𝑣𝑒𝑑 𝑎𝑟𝑒𝑎+ 𝑇𝑜𝑡𝑎𝑙 𝑟𝑜𝑜𝑓 𝑎𝑟𝑒𝑎

Use any combination of nonroof, high-reflectance roof, and vegetative roof strategies so that the weighted sum of site design strategies is greater than or equal to the sum of the total pavement and roof areas. Each surface may only be counted once, even if it is addressed through multiple strategies.

Nonroof measures

  • Shade over pavement areas, measured in plain view at noon, with existing or new plants, assuming 10-year canopy width, or vegetated structures. Planting or vegetated structures must be in place at the time of occupancy permit.

U.S. Green Building Council LEED v5 Reference Guide for Building Design and Construction, April 2025 Launch Edition 143