855773644-LEED-v5-BD-C-Reference-Guide-Launch-Edition - Page 162

Extracted Content

Light Trespass

Do not exceed the following luminaire backlight and glare ratings (based on the specific light source installed in the luminaire), as defined in IES TM-15-11, Addendum A, based on the mounting location and distance from the lighting boundary.

Table 2. Maximum backlight and glare ratings

Col1MLO lighting zoneCol3Col4Col5Col6
Luminaire mountingLZ0LZ1LZ2LZ3LZ4
Allowed backlight ratingsAllowed backlight ratingsAllowed backlight ratingsAllowed backlight ratingsAllowed backlight ratings
> 2 mounting heights from lighting boundaryB1B3B4B5B5
1 to 2 mounting heights from lighting boundary
and properly oriented
B1B2B3B4B4
0.5 to 1 mounting height to lighting boundary and
properly oriented
B0B1B2B3B3
< 0.5 mounting height to lighting boundary and
properly oriented
B0B0B0B1B2
Allowed glare ratingsAllowed glare ratingsAllowed glare ratingsAllowed glare ratingsAllowed glare ratings
Building mounted > 2 mounting heights from any
lighting boundary
G0G1G2G3G4
Building mounted = 1–2 mounting heights from
any lighting boundary
G0G0G1G1G2
Building mounted = 0.5–1 mounting heights from
any lighting boundary
G0G0G0G1G1
Building mounted < 0.5 mounting heights from
any lighting boundary
G0G0G0G0G1
All other luminairesG0G1G2G3G4

AND

Internally Illuminated Exterior Signage

Do not exceed the maximum luminance level of internally illuminated signage during nighttime hours according to Table 3.

Table 3. Maximum sign luminance

MLO lighting zoneSignage light output
LZ050 cd/m2
LZ150 cd/m2
LZ2100 cd/m2
LZ3200 cd/m2
LZ4350 cd/m2

U.S. Green Building Council LEED v5 Reference Guide for Building Design and Construction, April 2025 Launch Edition 152