855773644-LEED-v5-BD-C-Reference-Guide-Launch-Edition - Page 197

Extracted Content

Commercial kitchen equipmentCol2Requirement (IP)Requirement (SI)
Flight machineENERGY STAR®ENERGY STAR® or
performance equivalent
Food steamerBoilerless/
connectionless
≤ 1.7 gal/hr/pan, including
condensate cooling water
≤ 6.4 liters/hr/pan including
condensate cooling water
Food steamerSteam generator≤ 2.2 gal/hr/pan, including
condensate cooling water
≤ 8.3 liters/hr/pan including
condensate cooling water
Combination
oven
Countertop or
stand
ENERGY STAR®ENERGY STAR® or
performance equivalent
Combination
oven
Roll-inENERGY STAR®ENERGY STAR® or
performance equivalent
Food waste
disposer
Disposer3–8 gpm, full load condition;
10-minute automatic shutoff
or 1 gpm, no-load condition
11–30 lpm, full load condition;
10-minute automatic shutoff
or 3.8 lpm, no-load condition
Food waste
disposer
Scrap collectorMaximum 2 gpm makeup
water
Maximum 7.6 lpm makeup
water
Food waste
disposer
PulperMaximum 2 gpm makeup
water
Maximum 7.6 lpm makeup
water
Food waste
disposer
Strainer basketNo additional water usageNo additional water usage

Table 15. Compliant laboratory and medical equipment

Lab equipmentRequirement (IP)Requirement (SI)
Reverse-osmosis water purifier75% recovery75% recovery
Steam sterilizerFor 60 in sterilizer: 6.3 gal/U.S.
tray
For 48 in sterilizer: 7.5 gal/U.S.
tray
For 1,520 mm sterilizer: 28.5
liters/DIN tray
For 1,220 mm sterilizer: 28.35
liters/DIN tray
Sterile process washer0.35 gal/U.S. tray1.3 liters/DIN tray
X-ray processor, 150 mm or
more in any dimension
Film processor water recycling unitFilm processor water recycling unit
Digital imager, all sizesNo water useNo water use

To use Table 16, the project must be connected to a municipal or district steam system that does not allow the return of steam condensate.

Table 16. Compliant municipal steam systems

Steam systemRequirement
Steam condensate disposalCool municipally supplied steam condensate (no return) to
drainage system with heat recovery system or reclaimed water
OROR
Reclaim and use steam condensate100% recovery and reuse

AND/OR

U.S. Green Building Council LEED v5 Reference Guide for Building Design and Construction, April 2025 Launch Edition 187