855773644-LEED-v5-BD-C-Reference-Guide-Launch-Edition - Page 311

Extracted Content

Energy and Atmosphere Credit

ENHANCED ENERGY EFFICIENCY

EAc3

New Construction (1–10 points): 8 points are required for LEED BD+C: New Construction Platinum projects Core and Shell (1–7 points): 5 points are required for LEED BD+C: Core and Shell Platinum projects

INTENT

To design buildings that minimize energy use to reduce the environmental damage caused by resource extraction, air pollution, and greenhouse gas emissions and to facilitate the transition to a clean energy future.

REQUIREMENTS: NEW CONSTRUCTION
Achievement pathwaysPoints
New Construction1–10
Option 1. Prescriptive Path1–10
Path 1. Regulated Loads1–7
Case 1.ASHRAE 90.1-20191–5
OR
Case 2.ASHRAE 90.1-20224–7
AND/OR
Path 2. Plug and Process Loads (PPL)1–4
Case 1. Plug Load Management1
AND/OR
Case 2. Efficient Plug and Process Load Equipment1–4
OR
Case 3. Plug and Process Load Exceptional Calculation1–4
OR
Option 2. Energy Simulation1–10
Path 1. Percentage Reduction Excluding On-Site Renewable
Contribution
1–10
OR
Path 2. Percentage Reduction Including On-Site Renewable
Contribution
1–10

Option 1. Prescriptive Path (1–10 points)

PATH 1. REGULATED LOADS (1–7 POINTS)

Points are awarded according to Table 1 below, using either Case 1 or Case 2.

U.S. Green Building Council LEED v5 Reference Guide for Building Design and Construction, April 2025 Launch Edition 301