855773644-LEED-v5-BD-C-Reference-Guide-Launch-Edition - Page 466
Extracted Content
Table 1. Space types in EQ credits
| Space category | Prerequisite or credit |
|---|---|
| Occupied space | EQp2: Fundamental Air Quality EQc1: Enhanced Air Quality EQc2: Occupant Experience EQc5: Air Quality Testing and Monitoring |
| Regularly occupied space | EQc2: Occupant Experience EQc1: Enhanced Air Quality EQc4: Resilient Spaces EQc5: Air Quality Testing and Monitoring |
| Quiet space | EQc2: Occupant Experience |
| Classroom and core learning spaces | EQc2: Occupant Experience |
U.S. Green Building Council LEED v5 Reference Guide for Building Design and Construction, April 2025 Launch Edition 456