if desired. Calculate ASEnet1000,250 for each regularly occupied space. ASE is only calculated on a room-by-room basis.
Regularly occupied spaces with ASEnet(1000,250h) greater than 20%
Based on IES’s experience to date and analysis of the study data, an ASEnet of 20% or higher is a level of concern. For spaces where ASEnet exceeds 20%, projects must work with the designer to consider architectural methods to reduce the risk of sunlight penetration or consider the use of an automated daylight management system in as many window areas necessary to guarantee that it can avoid excessive occurrence of direct sunlight within the space.
Auditoriums
- Auditoriums may be excluded from the daylight requirements.
DOCUMENTATION
| Project types | Options | Paths Path 1. Integrated Biophilic Design | Documentation |
|---|---|---|---|
| All | Option 1. Biophilic Environment | Option 1. Biophilic Environment | Report/narrative identifying, classifying, and explaining each of five biophilic design principles incorporated into the project using the LEED v5 Indoor biophilic design Template. Evidence of the project’s indoor biophilic design features (for example any one of the following: contract documents, photographs, renderings, architectural mood board). |
| All | Option 1. Biophilic Environment | Path 2. Quality Views | Percentage of regularly occupied area with access to views (%) |
| All | Option 1. Biophilic Environment | Path 2. Quality Views | LEED v5 Quality Views calculator or a quality view simulation report. |
| All | Option 1. Biophilic Environment | Path 2. Quality Views | Architectural drawings that demonstrate direct access to the view and qualifying distance from glazing or a quality view simulation report and report checklist. |
| All | Option 2. Adaptable Environment | All | Report/narrative identifying, classifying, and explaining each variability and/or optionality strategy for thermal, sound, and lighting environments. |
| All | Option 2. Adaptable Environment | All | Optional evidence of variability and/or optionality strategy for thermal, sound, and lighting environments (for example, contract documents, photographs, product information from the manufacturer). |
| All | Option 2. Adaptable Environment | All | Identification of one or more accessible quiet space. |
| All | Option 2. Adaptable Environment | All | Identification of the additional adaptability strategy in the project (prospect areas, furniture, permanently installed fixtures, outdoor transitional space). |
U.S. Green Building Council LEED v5 Reference Guide for Building Design and Construction, April 2025 Launch Edition 503