If the TVOC levels exceed 500 µg/m3, investigate for potential issues by comparing the individual volatile organic compound (VOC) levels from the GC/MS results to associated cognizant authority health-based limits. Correct any identified issues and retest if necessary.

Test for the individual VOCs listed in Table 3 using an allowed test method and demonstrate that the contaminants do not exceed the concentration limits listed in the table. Laboratories that conduct the tests must be accredited under ISO/IEC 17025 for the test methods they use.

Table 3. Volatile organic compound limits

Contaminant (CAS#)Concentration limit
(µg/m3)
Allowed test methods
Formaldehyde 50-00-020 µg/m3 (16 ppb)ISO 16000-3, 4
EPA TO-11a
EPA comp. IP-6A
ASTM D5197-16
Acetaldehyde 75-07-0140 µg/m3140 µg/m3
Benzene 71-43-23 µg/m3ISO 16000-6
EPA IP-1
EPA TO-17
EPA TO-15
ISO 16017-1, 2
ASTM D6196-15
Hexane (n-) 110-54-37000 µg/m37000 µg/m3
Naphthalene 91-20-39 µg/m39 µg/m3
Phenol 108-95-2200 µg/m3200 µg/m3
Styrene 100-42-5900 µg/m3900 µg/m3
Tetrachloroethylene 127-18-435 µg/m335 µg/m3
Toluene 108-88-3300 µg/m3300 µg/m3
Vinyl acetate 108-05-4200 µg/m3200 µg/m3
Dichlorobenzene (1,4-) 106-46-7800 µg/m3800 µg/m3
Xylenes — total 108-38-3, 95-47-6, and
106-42-3
700 µg/m3700 µg/m3

AND/OR

OPTION 2. CONTINUOUS INDOOR AIR MONITORING (1 POINT)

Provide indoor air monitors for all the following parameters:

  • Carbon dioxide (CO2)

  • Particulate matter (PM2.5)

  • Total volatile organic compounds

U.S. Green Building Council LEED v5 Reference Guide for Building Design and Construction, April 2025 Launch Edition 523