9. NORMATIVE REFERENCES
Air Conditioning, Heating and Refrigeration Institute (AHRI) 2311 Wilson Blvd., Arlington, VA 22201 (+1) 703-524-8800; www.ahrinet.org
AHRI 1060 (2018) Performance Rating of Air-to-Air Exchangers for Energy Recovery Ventilation Equipment
Air Movement and Control Association International, Inc. (AMCA) 30 West University Drive Arlington Heights, IL 60004-1893, United States 1-847-394-0150; www.amca.org
Section
5.13.3.2.5, 5.13.3.3.2
AMCA 500-L-15 Laboratory Methods of Testing Louvers for Rating 5.4.2
American Industrial Hygiene Association (AIHA) 3141 Fairview Park Drive, Suite 777 Falls Church, VA 22042, United States (703) 849-8888; www.aiha.org
ANSI/AIHA Z9.5-2012 Standard for Laboratory Ventilation 5.4.1.4, 6.2.1.1.5, 6.5.1, B1.1
ASHRAE 1791 Tullie Circle NE Atlanta, GA 30329, United States 1-404-636-8400; www.ashrae.org
ANSI/ASHRAE Standard 41.2 (2018) Standard Methods for Air Velocity and Airflow Measurement Table 8-1
ANSI/ASHRAE Standard 52.2 (2017) Method of Testing General Ventilation Air-Cleaning Devices for Removal Efficiency by Particle Size
5.5, 6.1.4.1, 6.1.4.2
7.2.2, Table 8-1
ANSI/ASHRAE Standard 111-2008 (RA 2017)
Measurement, Testing, Adjusting, and Balancing of Building HVAC Systems
ANSI/ASHRAE/ASHE Standard 170 (2017) Ventilation for Health Care Facilities 6.2.1
ANSI/ASHRAE Standard 188 (2018) Legionellosis: Risk Management for Building Water Systems 5.20
ASTM International 100 Barr Harbor Dr. West Conshohocken, PA 19428-2959, United States 1-610-832-9585; www.astm.org
ASTM C1338 (2014) Standard Test Method for Determining Fungi Resistance of Insulation Materials and Facings
ASTM D3273 (2016) Standard Test Method for Resistance to Growth of Mold on the Surface of Interior Coatings in an Environmental Chamber
ASTM D6345 (2010) Standard Guide for Selection of Methods for Active, Integrative Sampling of Volatile Organic Compounds in Air
ASTM D5197 (2016) Standard Test Method for Determination of Formaldehyde and Other Carbonyl Compounds in Air (Active Sampler Methodology)
Chartered Institution of Building Services Engineers (CIBSE) 222 Balham High Road London SW12 9BS United Kingdom +44 (0)20 8675 5211; www.cibse.org
5.11.1
5.11.1
Table 7-1
Table 7-1
CIBSE AM10 (2005) Natural Ventilation in Non-Domestic Buildings 6.4.1.6.2
Facility Guidelines Institute (FGI) https://fgiguidelines.org
2018 Guidelines for Design and Construction of Outpatient Facilities 3.1