(This appendix is not part of this standard. It is merely informative and does not contain require- ments necessary for conformance to the standard. It has not been processed according to the ANSI requirements for a standard and may contain material that has not been subject to public review or a consensus process. Unresolved objectors on informative material are not offered the right to appeal at ASHRAE or ANSI.)
INFORMATIVE APPENDIX L COMPLIANCE
This appendix contains compliance suggestions that are intended to assist users and enforcement agencies in applying this standard.
L1. SECTION 4
Is documentation of outdoor air quality included as required in Section 4.3?
L2. SECTION 5
Are air balancing provisions included in design documentation as required in Section 5.10? If the system is a plenum system, are provisions for providing minimum breathing zone airflow specified? Do exhaust ducts comply with the requirements of Section 5.14? Are ventilation systems controls specified as per Section 5.18? Do specifications include resistance to mold and erosion for airstream surfaces per Section 5.11? Are separation distances between outdoor air intakes and sources listed and in compliance with Section 5.4? Is there any noncombustion equipment that requires exhaust (Section 5.16)? Is combustion air provided for fuel-burning appliances (Section 5.15)? Are appropriate filters specified upstream of cooling coils or wetted surfaces (Section 5.5)? Are dehumidification capability and building exfiltration calculations provided (Section 5.12)? Do specifications for drain pans comply with requirements of Section 5.7? Are coils specified per the requirements of Section 5.6? If present, do humidifiers and water spray systems comply with the requirements of Section 5.8? Is access provided for inspection, cleaning, and maintenance of all ventilation equipment and air distribution equipment (Section 5.19)? Is moisture management (Section 5.1) included in building envelope design, including specifically, weather barrier; vapor retarder; sealing exterior joints, seams, and penetrations; and insulation on pipes, ducts, or other surfaces whose temperatures are expected to fall below dew point of surrounding air? If there is an attached parking garage, do airflow control measures comply with requirements of Section 5.2? Is recirculation from spaces containing Class 2 air limited to spaces with the same purpose and with the same pollutants following requirements of Section 5.13.3.2? Is air from spaces containing Class 3 air contained and not transferred to any other space (Section 5.13.3.3)? Is all air from spaces containing Class 4 air exhausted directly to the outdoors (Section 5.13.3.4)? If ETS is expected to be present, does the design comply with all separation requirements of Section 5.3?
L3. SECTION 6 VENTILATION RATE PROCEDURE
Are occupancy categories consistent with the space design documents? Are there any unusual sources of contaminants or compounds? If yes, ventilation must be added per Section 6.3.5.
ANSI/ASHRAE Standard 62.1-2022 67