LEED v5 O+M Rating System_February 2026 - Page 048
Extracted Content

Energy and Atmosphere Credit
OPTIMIZED ENERGY PERFORMANCE
EAc2
2–12 points
INTENT
To operate buildings that minimize energy use to reduce the environmental damage caused by resource extraction, air pollution, and greenhouse gas emissions and facilitate the transition to a clean energy future.
REQUIREMENTS
| Achievement Pathways | Points |
|---|---|
Existing Buildings | 2–12 |
Option 1. ENERGY STAR Score | 2–12 |
OR | |
Option 2. Energy Use Intensity Targets | 2–12 |
OR | |
Option 3. Performance Relative to Historical Baseline | 2–12 |
Refer to EAp3: Minimum Energy Performance for requirements associated with each path. No further data entry or calculations are required for this credit.
-
Property types eligible to receive an ENERGY STAR score in the U.S. and Canada must comply with Option 1.
-
Property types eligible to receive an ENERGY STAR score outside the U.S. and Canada must comply with either Option 1 or Option 2.
-
Property types referenced in Appendix II, Table 1, that are ineligible to receive an ENERGY STAR score must comply with either Option 2 or Option 3.
-
All other property types must comply with Option 3 or see additional guidance/requirements.
Option 1. ENERGY STAR Score (2–12 points)
Points are awarded for ENERGY STAR scores of 69 or above from the Environmental Protection Agency Portfolio Manager tool, according to Table 1.
Table 1. Points for ENERGY STAR Performance Rating (2–12 points)
| ENERGY STAR Rating | Points |
|---|---|
69 | 2 |
U.S. Green Building Council LEED v5 Reference Guide for Operations and Maintenance, November 2025 Edition 42