855773520-LEED-v5-ID-C-Reference-Guide-Launch-Edition-1 - Page 054

Extracted Content

Rating systemCreditPoints earnedEquivalent ID+C
points
4–6

4
LEED v5_LTc1: Compact and Connected _
Development
11
LEED v5_LTc1: Compact and Connected _
Development
2–4
4
LEED v5_LTc1: Compact and Connected _
Development
5–68

OR

Meet any combination of the options below for a maximum of 8 points.

Option 2. Surrounding Density (1–3 points)

Locate in a building where the surrounding existing density within 0.25 miles (400 meters) offset of the project boundary meets the values in Table 2. Use either the “separate residential and nonresidential densities” or the “combined density” values.

Table 2. Points for average existing density within 0.25 miles (400 meters)

Combined densityCol2Separate densityCol4Col5Points
Sq. ft. per
acre of
buildable
land
Sq. m. per
hectare of
buildable land
Residential
density
(DU/acre)
Residential
density
(DU/hectare)
Nonresidential
density (FAR)


22,000
5,050
7
17.5
0.5
2
35,0008,03512300.83

NOTE: DU = dwelling unit; FAR = floor area ratio

AND/OR

Option 3. Access to Transit (1–5 points)

Locate any functional entry of the building in which the project is located within either:

  • A walking distance of 0.25 miles (400 meters) by existing or planned bus, streetcar, or informal transit stops

  • A walking distance of 0.25 miles (800 meters) by existing or planned bus rapid transit stops, passenger rail stations (i.e., light, heavy, or commuter rail), or commuter ferry terminals

The transit service at these stops and stations in aggregate must meet the minimums listed in Table 3.

U.S. Green Building Council LEED v5 Reference Guide for Interior Design and Construction, April 2025 Launch Edition 43