Table 3. Standards for appliances

ApplianceCol2RequirementCol4
Residential clothes washer
Residential clothes washer
ENERGY STAR® or performance equivalent
ENERGY STAR® or performance equivalent
Commercial clothes washer
Commercial clothes washer
ENERGY STAR® for commercial clothes washers with ≤
8.0 cubic feet (227 liters) of capacity or performance
equivalent
ENERGY STAR® for commercial clothes washers with ≤
8.0 cubic feet (227 liters) of capacity or performance
equivalent
Residential dishwashers (standard and
compact)
Residential dishwashers (standard and
compact)

ENERGY STAR® or performance equivalent

ENERGY STAR® or performance equivalent
Prerinse spray valves
Prerinse spray valves
≤ 1.3 gpm (4.9 lpm)
≤ 1.3 gpm (4.9 lpm)
Ice machine
Ice machine
ENERGY STAR® or performance equivalent and use either
air-cooled or closed-loop cooling, such as chilled or
condenser water system

ENERGY STAR® or performance equivalent and use either
air-cooled or closed-loop cooling, such as chilled or
condenser water system

Commercial Kitchen Equipment

Commercial Kitchen Equipment


Requirement (IP)
Requirement (SI)
Dishwasher
Undercounter≤ 1.6 gal/rack≤ 6.0 liters/rack
Dishwasher
Stationary, single
tank, door
≤ 1.4 gal/rack
≤ 5.3 liters/rack
Dishwasher
Single tank,
conveyor
≤ 1.0 gal/rack
≤ 3.8 liters/rack
Dishwasher
Multiple tank,
conveyor
≤ 0.9 gal/rack≤ 3.4 liters/rack
Dishwasher
Flight machine
≤ 180 gal/hr
≤ 680 liters/hr
Food steamer
Boilerless/
connectionless
≤ 2 gal/hr/pan≤ 7.5 liters/hr/pan
Food steamer

Steam generator
≤ 5 gal/hr/pan
≤ 19 liters/hr/pan
Combination
oven
Countertop or stand
≤ 1.5 gal/pan
≤ 5.7 liters/pan
Combination
oven
Roll-in≤ 1.5 gal/pan≤ 5.7 liters/pan

Table 4. Standards for processes

ProcessRequirement
Heat rejection and cooling
No once-through cooling with potable water for any equipment or
appliances that reject heat
Discharge water
temperature tempering
Where local requirements limit the discharge temperature of fluids into
a drainage system, use a tempering device that runs water only when
the equipment discharges hot water.
OR
Provide a thermal recovery heat exchanger that cools drained
discharge water below code-required maximum discharge
temperatures while simultaneously preheating inlet makeup water.
OR
If fluid is steam condensate, return it to boiler.
Venturi-type flow-through
vacuum generators or
aspirators

Use no device that generates a vacuum by means of water flow
through the device into the drain.

U.S. Green Building Council LEED v5 Reference Guide for Interior Design and Construction, April 2025 Launch Edition 73