operators and tenants, the approach for resolving detected leaks, and a communication plan to alert building occupants when repairs impact the building.

Flush fixture leak detection requirements For the flush fixtures, install sensors or meters for at least 50% of the flush fixtures identified in WEp1: Minimum Water Efficiency . Install the device at the flush fixture for an individual toilet room, such as a unisex or family restroom. A single device that monitors all flush fixtures for group restrooms is acceptable.

DOCUMENTATION
Project
types
OptionsPathsDocumentation

All
Option 1.
Meters
All
Contract documents highlighting the locations and types of the
project’s permanent water meters or submeters that measure the
total water consumption for each water source for the tenant space
(for example, water supply system drawings).

All
Option 1.
Meters
All

Commitment from the project owner to share with USGBC the
resulting tenant space water usage data at least annually.

All
Option 1.
Meters
All

Confirmation that the data is accessible by the tenant.
All
Option 2.
Submeters
All
Confirmation that all submeters are capable of recording data at
least hourly (for example, product information from the
manufacturer and/or contract documents).
All
Option 2.
Submeters
All
Contract documents highlighting the locations and types of the
project’s permanent water meters for each applicable subsystem
(for example, water supply system drawings).
All
Option 2.
Submeters
All

Contract documents demonstrating that facility manager and/or
tenant(s) will be able to access the submeter data in real-time via
local network, BMS, cloud service, app, or online database, and
that all submeters are capable of recording data at least hourly.
All
Option 2.
Submeters
All
Calculation demonstrating the percentage of metered indoor
fixtures/fittings.
AllOption 3.
Leak
Detection
Sensors
AllContract documents highlighting the locations and types of the
project’s permanent water flow meters/sensors for the project’s
flush fixtures in the tenant space (for example, water supply
system drawings).
AllOption 3.
Leak
Detection
Sensors
All
Narrative or documents detailing the leak detection system
specifications, for when and how an alarm is triggered (for
example, the Owner’s Project Requirements, BOD, Contract
Documents, or product information from the manufacturer)
AllOption 3.
Leak
Detection
Sensors
All
The project’s action plan that addresses how the tenant will have
access to data in real-time and will address and remedy any
detected leak.
AllOption 3.
Leak
Detection
Sensors
All
Calculation demonstrating the percentage of flush fixtures with leak
detection.

U.S. Green Building Council LEED v5 Reference Guide for Interior Design and Construction, April 2025 Launch Edition 82