855773520-LEED-v5-ID-C-Reference-Guide-Launch-Edition-1 - Page 184

Extracted Content

The project achieves 27 incremental energy credits above the minimum required for prescriptive method compliance, which exceeds the 25 required for two LEED points.

ECinc = Minimum (ECeligible, ECtotal − ECreq)

ECinc = Minimum (52, 52 − 25) = 27 Example 2. Substantial alteration retail project in climate zone 4A Renewable energy used to earn energy credits for prerequisite compliance.

The project referenced in Example 1 adds a roof-mounted PV array with a rated capacity of at least 0.75 W/sq. feet (8.1 W/sq. m.) of the project’s gross floor area, achieving 15 energy credits for measure R01: On-site Renewable Energy, and maximizing the combined allowable ASHRAE 90.1-2022, Section 11 contribution for renewable and load management credits. The project achieves 67 total energy credits per ASHRAE 90.1-2022, Section 11.

ECtotal = EC_H02 + EC_L04 + EC_L06 + EC_R01

ECtotal = 28 + 4 + 20 + 15 = 67 Of these energy credits, 52 are from measures eligible for LEED points (H02, L04, and L06). Therefore, the project achieves 42 incremental energy credits above the minimum required for prescriptive method compliance, which exceeds the 38 required for three LEED points.

ECinc = Minimum ( ECeligible, ECtotal - ECreq )

ECeligible = Minimum ( 52, 67 - 25 ) = 42

ELIGIBLE MEASURES FOR PATH 1. REGULATED LOADS Table 1. Eligible measures from ASHRAE 90.1-2022 Section 11.5.2 for LEED points

HVAC MeasuresLighting Measures

H01: HVAC System Performance
Improvement (ASHRAE 90.1-2022,
Addendum J)*

L01. Lighting System Performance**

H02: HVAC Heating Performance
Improvement.
L02: Lighting Dimming and Tuning.

H03: HVAC Cooling Performance
Improvement.
L03: Increase Occupancy Sensor.

H04: Residential HVAC Controls.
L04: Increase Daylight Area.

H05: Ground-Source Heat Pump.

L05: Residential Light Controls.

H06: DOAS/Fan Controls.
H07: Guideline 36 Sequences.

L06: Light Power Reduction.

SWH Measures
Load Management Measures
W01: SHW Preheat Recovery.
G07: Building Mass/Night Flush.

W02: Heat-Pump Water Heater.

W02: Heat-Pump Water Heater.

W03: Efficient Gas Water Heater.

W03: Efficient Gas Water Heater.

W04: SWH Pipe Insulation.

W04: SWH Pipe Insulation.

W05: Point-of-Use Water Heaters.

W05: Point-of-Use Water Heaters.

U.S. Green Building Council LEED v5 Reference Guide for Interior Design and Construction, April 2025 Launch Edition 173