ASHRAE-90.1-2022- - Page 054

Extracted Content

NonresidentialResidentialSemiheated
** Opaque Elements**

Assembly
Maximum
Insulation
Min. R-Value
** Opaque Elements**

Assembly
Maximum
Insulation
Min. R-Value
Assembly
Maximum
Insulation
Min. R-Value
Assembly
Maximum
Insulation
Min. R-Value
Insulation entirely
above deck
U-0.032
R-30_c.i._
Metal building a
U-0.037
R-19 + R-11_Ls_ or
R-25 + R-8_Ls_
Attic and other
U-0.021
R-49
Roofs
U-0.032
R-30_c.i._
U-0.037
R-19 + R-11_Ls_ or
R-25 + R-8_Ls_
U-0.021
R-49
U-0.093
R-10_c.i._
U-0.082
R-19
U-0.034
R-30
Wa
Mass
U-0.104
R-9.5_c.i._
Metal building
U-0.060
R-0 + R-15.8_c.i._
Steel-framed
U-0.064
R-13 + R-7.5_c.i._
Wood-framed and other
U-0.064
R-13 + R-3.8_c.i._ or R-20
lls, above Grade
U-0.090
R-11.4_c.i._
U-0.050
R-0 + R-19_c.i._
U-0.064
R-13 + R-7.5 c.i
U-0.064
R-13 + R-3.8_c.i._ or R-20
U-0.580
NR
U-0.162
R-13
U-0.124
R-13
U-0.089
R-13
Wa
Below-grade wall
C-0.119
R-7.5_c.i._
ll, below Grade
C-0.092
R-10_c.i._
C-1.140
NR
Mass
U-0.057
R-14.6_c.i._
Steel joist
U-0.038
R-30
Wood-framed and other
U-0.033
R-30
Floors
U-0.051
R-16.7_c.i._
U-0.038
R-30
U-0.033
R-30
U-0.107
R-6.3_c.i._
U-0.052
R-19
U-0.051
R-19
Slab
Unheated
F-0.520
R-15 for 24 in.
Heated
F-0.843
R-20 for 24 in.
-on-Grade Floors
F-0.520
R-15 for 24 in.
F-0.688
R-20 for 48 in.
F-0.730
NR
F-0.900
R-10 for 24 in.

Swinging
U-0.370

Nonswinging
U-0.310
Opaque Doors
U-0.370

U-0.310
U-0.370

U-0.360
Fenestration
Assembly
Max. U
Assembly
Max. SHGC
Assembly
Min.
VT/SHGC
Nonresidential
Assembly
Max. U
Assembly
Max. SHGC
Assembly
Min.
VT/SHGC
Residential
Assembly
Max. U
Assembly
Max.
SHGC
Assembly
Min.
VT/SHGC
Semiheated
Vertical Fene
Fixed
0.36
0.36
1.10
(for all
types)
Operable
0.45
0.33
Entrance door
0.63
0.33
_ stration_, 0% to 40% of_Wall_
0.36
0.36
1.10
(for all
types)
0.45
0.33
0.63
0.33
0.50
NR
(for all
types)
NR
(for all
types)
0.65
0.77
Skyligh
All types
0.50
0.40
NR
t, 0% to 3% of_Roof_
0.50
0.40
NR
0.75
NR
NR
  • The following definitions apply: c.i. = continuous insulation (see Section 3.2), FC = filled cavity (see Section A2.3.2.5), Ls = liner system (see Section A2.3.2.4); NR = no (insulation) requirement. a. When using the R-value compliance method for metal building roofs, a thermal spacer block is required (see Section A2.3.2).

52 ANSI/ASHRAE/IES Standard 90.1-2022 (I-P)