ASHRAE-90.1-2022- - Page 329

Extracted Content

Opaque Elements

Performance Rating Method BuildingEnvelope Requirements for Climate Z
NonresidentialResidential
Assembly MaximumAssembly Maximum

Roofs

Walls, Above-Grade

Steel-framed U-0.124 U-0.124 U-0.352

Wall, Below-Grade

Floors

Steel-joist U-0.052 U-0.052 U-0.350

Slab-on-Grade Floors

Unheated F-0.730 F-0.730 F-0.730

Col1Col2Col3Col4Opaque DoorsCol6Col7Col8Col9Col10
SwingingU-0.700U-0.700U-0.700U-0.700U-0.700U-0.700U-0.700U-0.700U-0.700
NonswingingU-1.450U-1.450U-1.450U-1.450U-1.450U-1.450U-1.450U-1.450U-1.450
FenestrationAssembly
Max. U
Assembly
Max. SHGC
Visible
Transmittance
Assembly
Max. U
Assembly
Max. SHGC
Visible
Transmittance
Assembly
Max. U
Assembly
Max. SHGC
Visible
Transmittance

Vertical Glazing, % of Wall

0%
to 10.0%
U -1.22
all
SHGC -0.25
all
VT -0.28
all
U -1.22
all
SHGC -0.39
all
VT -0.43
all
U -1.22
all
SHGC -0.40
all
VT -0.44
all
10.1%
to 20.0%
U_all_-1.22SHGCall-0.25VTall-0.28U_all_-1.22SHGCall-0.25VTall-0.28U_all_-1.22SHGCall-0.40VTall-0.44
20.1%
to 30.0%
U_all_-1.22SHGCall-0.25VTall-0.28U_all_-1.22SHGCall-0.25VTall-0.28U_all_-1.22SHGCall-0.40VTall-0.44
30.1%
to 40.0%
U_all_-1.22SHGCall-0.25VTall-0.28U_all_-1.22SHGCall-0.25VTall-0.28U_all_-1.22SHGCall-0.40VTall-0.44

Skylight All, % of Roof

0%
to 2.0%
U -1.36
all
SHGC -0.36
all
VT -0.40
all
U -1.36
all
SHGC -0.19
all
VT -0.21
all
U -1.36
all
SHGC -0.55
all
VT -0.61
all
2.1%+U_all_-1.36SHGCall-0.19VTall-0.21U_all_-1.36SHGCall-0.19VTall-0.21U_all_-1.36SHGCall-0.55VTall-0.61

ANSI/ASHRAE/IES Standard 90.1-2022 (I-P) 327