ASHRAE-90.1-2022- - Page 335

Extracted Content

Table G3.4-8 Performance Rating Method Building Envelope Requirements for Climate Zone 8*

Opaque Elements

NonresidentialResidential
Assembly MaximumAssembly Maximum

Roofs

Walls, Above-Grade

Steel-framed U-0.064 U-0.055 U-0.124

Wall, Below-Grade

Floors

Steel-joist U-0.038 U-0.032 U-0.052

Slab-on-Grade Floors

Unheated F-0.540 F-0.520 F-0.730

Col1Col2Col3Col4Opaque DoorsCol6Col7Col8Col9Col10
SwingingU-0.500U-0.500U-0.500U-0.500U-0.500U-0.500U-0.700U-0.700U-0.700
NonswingingU-0.500U-0.500U-0.500U-0.500U-0.500U-0.500U-1.450U-1.450U-1.450
FenestrationAssembly
Max. U
Assembly
Max. SHGC
Visible
Transmittance
Assembly
Max. U
Assembly
Max. SHGC
Visible
Transmittance
Assembly
Max. U
Assembly
Max. SHGC
Visible
Transmittance

Vertical Glazing, % of Wall

0%
to 10.0%
U -0.46
all
SHGC -0.40
all
VT -0.44
all
U -0.46
all
SHGC -0.40
all
VT -0.44
all
U -1.22
all
SHGC -0.40
all
VT -0.44
all
10.1%
to 20.0%
U_all_-0.46SHGCall-0.40VTall-0.44U_all_-0.46SHGCall-0.40VTall-0.44U_all_-1.22SHGCall-0.40VTall-0.44
20.1%
to 30.0%
U_all_-0.46SHGCall-0.40VTall-0.44U_all_-0.46SHGCall-0.40VTall-0.44U_all_-1.22SHGCall-0.40VTall-0.44
30.1%
to 40.0%
U_all_-0.46SHGCall-0.40VTall-0.44U_all_-0.46SHGCall-0.40VTall-0.44U_all_-1.22SHGCall-0.40VTall-0.44

Skylight All, % of Roof

0% to
2.0%
U -0.58
all
SHGC -0.55
all
VT -0.61
all
U -0.58
all
SHGC -0.55
all
VT -0.61
all
U -0.81
all
SHGC -0.55
all
VT -0.61
all
2.1%+U_all_-0.58SHGCall-0.55VTall-0.61U_all_-0.58SHGCall-0.55VTall-0.61U_all_-0.81SHGCall-0.55VTall-0.61

ANSI/ASHRAE/IES Standard 90.1-2022 (I-P) 333