To qualify as an adjacent site, at least a contiguous 25% of the project boundary must border parcels that are previously developed sites.
- Bordering rights-of-way do not constitute previously developed land; it is the status of the property on the other side of the right-of-way that contributes to the calculation. Any part of the boundary that borders a water body is excluded from the calculation.
Table 7. Points for Development and Adjacency
| Type of Site | Points |
|---|---|
| Previously developed site that was used for industrial or commercial purposes. | 1 |
Previously developed and adjacent site with bordering parcels currently used for industrial or commercial purposes. | 2 |
AND/OR
PATH 2. TRANSPORTATION RESOURCES (1–2 POINTS)
Locate the project on a site that has two of the following transportation resources for 1 point or all four of the following transportation resources for 2 points:
-
The site is within a 10-mile (16-kilometer) driving distance of a main logistics hub.
-
The site is within a one mile (1,600 meter) driving distance of an on-off ramp to a highway.
-
The site is within a one mile (1,600 meter) driving distance of an access point to an active freight rail line.
-
The site is served by an active freight rail spur.
A planned transportation resource must be sited, funded, and under construction by the date of the certificate of occupancy and complete within 24 months of that date.
Healthcare (1–6 points)
- Meet Options 1, 2, and/or 3 above.
AND/OR
Option 7. Surrounding Density (1 point)
Locate on a site where the surrounding existing density within 0.25 miles (400 meters) offset of the project boundary meets one of the following:
-
At least seven dwelling units per acre (17.5 DU per hectare) with a 0.5 floor area ratio. The counted density must be existing density, not zone density.
-
At least 22,000 square feet per acre (5,050 square meters per hectare) of buildable land.
U.S. Green Building Council LEED v5 Reference Guide for Building Design and Construction, November 2025 Edition 27