LEED v5 Interior Design and Construction Addenda

PageCategory and Prerequisite/Credit
Name
LocationIssuePost Date
50LTc2: Transportation Demand
Management
RequirementsSee February 2026 tracked changes Rating System document for all changes to this credit.2/20/2026
54LTc2: Transportation Demand
Management
Reference Guide ContentSee February 2026 Reference Guide for all changes to this section.2/20/2026
69LTc3: Electric VehiclesRequirementsID+C
Requirements, Option 2
Change the 9 to an 8 in “has an accessible parking space at least 9 feet (2.5 meters) wide”
2/20/2026
149EAc1: ElectrificationRequirements > Option 4 > Table 2In the “Base building minimum threshold” column, shift whole scale 1 point down for row-‘O+M’. (6 points —> 5 points; 5 points —> 4
points; 4 points —> 3 points; 2 points —> 1 point.)
2/20/2026
184EAc3: Renewable EnergyRequirements > Renewable Energy
Classifications > Tier 3
Under Tier 3, revise second bullet to be: Renewable fuels that are Green-e® Renewable Fuels certified or equivalent.2/20/2026
201EAc4: Enhanced CommissioningRequirements Explained > Option 1
> Timing of CxP engagement
Option 1 > Timing of CxP engagement
Delete the following sentence:
“If the CxP is engaged after pre-design, alternative measures must be taken to ensure alignment with the intent of the Standard 202
timeline.” and replace with the following sentence:
“In certain scenarios, it may be possible for the CxP to be engaged after pre-design and still meet the intent of the ASHRAE 202
timeline.”
2/20/2026
229MRp1: Planning for Zero Waste
Operations
Intent
Requirements
Change all (6) instances of “building” to “project” in the Intent and Requirements.2/20/2026
258MRc3: Low-Emitting MaterialsRequirements > Table 1In Table 1. Thresholds for Low-Emitting Materials:
The first row (for 1 point) should remain the same.
The second row (for 2 points) should read, “>90% of all products in each product category”
The third row (for 3 points) should read, “>80% of all products in each additional product category”
The fourth row (for 4 points) should read, “>80% of all products in each additional product category”
2/20/2026
258MRc3: Low-Emitting MaterialsRequirements
Requirements Explained >
Calculating Product Category
Achievement
Requirements:
- In the first sentence, remove phrase “permanently installed products,”
- Under Flooring and Insulation product category, delete all instances of “membrane”
- Under Furniture product category, delete “permanently installed” from the second bullet.
Requirements Explained:
Delete “membrane” from the first sentence in the fourth paragraph.
2/20/2026
262MRc3: Low-Emitting MaterialsRequirements ExplainedRevise the the last two sentences of the second paragraph to read as:
“Projects targeting two or four product categories must achieve low-emitting criteria for 90% or more of all products in each product
category. Projects targeting six or eight product categories must achieve low-emitting criteria for 80% or more of all products in each
additional product category.”
2/20/2026

Addenda LEED v5 Interior Design and Construction February 20, 2026

PDF Page 2

Open page note

2

PageCategory and Prerequisite/Credit
Name
LocationIssuePost Date
276MRc4: Building Product Selection
and Procurement

Requirements Explained > Table 1
In the Flooring row:
-Strike Terrazzo flooring from the examples of products.
-Remove the ‘s’ from ‘Laminates Flooring’ example.
-Remove ‘Wood and composite’ from ‘Wood and composite wood subflooring’ example. Add ‘Reused solid’ before ‘wood.’
-Remove Wall base example.
In the Wall row remove the following examples:
- Cubicle wall
- Window treatments
2/20/2026
339EQc3: Accessibility and InclusionRequirements ExplainedAdd “(ONLY FOR PROJECTS IN REGIONS WITH NO ACCESSIBILITY CODE)” after RAMPS FOR ACCESSIBLE ROUTES AND
ENTRANCES, CLEAR WIDTH FOR HUMAN PASSAGE, and FRONT APPROACH WHEELCHAIR ACCESSIBLE SECTION
AND

Delete ” as mandated by the Americans with Disabilities Act (ADA) in the first sentence under RAMPS FOR ACCESSIBLE ROUTES
AND ENTRANCES (ONLY FOR PROJECTS IN REGIONS WITH NO ACCESSIBILITY CODE)
2/20/2026
341EQc3: Accessibility and InclusionRequirements ExplainedBD+C and ID+C:
Requirements Explained > Table 3. or Table 2.
Change “single-use restroom OR one multi-use” to “single-user restroom OR one multi-user” in the second row.
2/20/2026
356EQc5: Air Quality Testing and
Monitoring
Requirements Explained > OPTION
2. CONTINUOUS INDOOR AIR
MONITORING > Monitor
Specifications
Under the Monitor specifications section, delete “Grade B” after “UL 2095” and change “2095” to “2905” in the last section of the
last sentence.
2/20/2026

*Shaded rows denote rating system changes.

Note: The online version of the rating system takes precedent over the rating system portions of the LEED v5 project guidance and application; project teams are required to adhere to the rating system and rating system

addenda effective at the time of the project’s registration date.